Back to the top page
Back to Measurement Equipments 3
FM-AM Standard Signal Generator MSG-2570 ( Meguro )
[Outline] [Trouble-shoots]
[Reset the control logic board] [Polish
the contact
of the keys] [Replace an
operational amplifier]
Fig1. The rear panel. | Fig.2 Remove the rear panel. |
Fig.3 Remove the cover of the logic board. | Fig.4 The mcu (6809!) , ROM and the back up battery. At first , the voltage of the back up battery was under 2V. |
Fig.5 Push the INITIAL SET key to reset the logic board. |